Re: [STDS-802-3-EPOC] Line coding for EPoC



Hi Marek,
Thanks for your preso and recommendation.
Referencing your slide 8, in your opinion, are there additional portions of Clause 49 64b/66b encoding/decoding that would be not applicable/ reusable for us?  E.g., you've already excluded scrambler and gearbox; what else?
Alan

From: Marek Hajduczenia [mailto:marek.hajduczenia@xxxxxx]
Sent: Thursday, March 07, 2013 5:31 AM
To: STDS-802-3-EPOC@xxxxxxxxxxxxxxxxx
Subject: [STDS-802-3-EPOC] Line coding for EPoC

Dear colleagues,

I prepared a presentation (as attached) focusing on the topic of line coding for EPoC, why it is needed and what our options are looking at other existing Ethernet standards. I also included overview of 64b/66b line code with some details so that people can start thinking about this topic. My belief is that we can reuse 64b/66b line coding in EPoC to guarantee good code-word alignment and have to do absolutely nothing to develop a new line code for EPoC. The same approach was taken in 10G-EPON and worked just great - no development errors were committed, and companies could just reuse their existing implementations from 10GE and other high speed Ethernet PHYs.

The decision on the line code is important, since the selection of the line code influences other choices, including the FEC code word size, mapping of individual data vectors into the FEC code word, as well as the following OFDM symbol size.

I plan to submit this contribution to the upcoming meeting in Orlando and I would appreciate your feedback and comments ahead of time.

Thank you in advance
regards
Marek Hajduczenia, PhD

ZTE Portugal
Standard Development and Industry Relations
Edifício Amoreiras Plaza,
Rua Carlos Alberto da Mota Pinto, nr. 9 - 6 A,
1070-374 Lisbon, Portugal

Office: +351 213 700 090
Fax: + 351 213 813 349
Mobile: +351 961 121 851 (Portugal)



________________________________

<="" p="">

________________________________________________________________________

To unsubscribe from the STDS-802-3-EPOC list, click the following link:
https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-3-EPOC&A=1