Thread Links | Date Links | ||||
---|---|---|---|---|---|
Thread Prev | Thread Next | Thread Index | Date Prev | Date Next | Date Index |
All, Thanks to everyone who attended the call today. We had additional discussion on the TDD PLC proposal from Nicola. We had positive results on 5 Straw polls. #12: The 8 (4K FFT) or 16 (8K FTT) sub-carriers for the downstream PLC will be adjacent carriers. Y:11 N:0 A:2 #13: The downstream PLC must be placed within the minimum EPoC spectrum block (currently 24MHz) Y: 12 N:0 A:0 #14: The downstream PLC locations will be on a 1MHz grid (interval). Y:8 N:0 A:4 #15: The PLC preamble will repeat on a configured PLC Cycle Time. In FDD mode, the PHY Cycle Time will be time aligned with the staggered pilot pattern. Y:10 N:0 A: 2 #16: In TDD mode, the PHY Cycle Time will be time aligned with the TDD Cycle. The PHY Cycle Time may be multiples of the TDD Cycle. Y:10 N:0 A:2 #17: PLC Preamble Symbols will have a single fixed pattern & modulation order. The PLC Preamble will not have error correction for burst noise. Infrequent errors in the preamble shouldn't prevent decoding of the PLC after locking onto the PLC cycle. Y:9 N:0 A:0 Mark; please post the attached slides. Thanks, Ed... From: Ed (Edward) Boyd [mailto:ed.boyd@xxxxxxxxxxxx] Sent: Wednesday, April 24, 2013 10:51 AM To: STDS-802-3-EPOC@xxxxxxxxxxxxxxxxx Subject: [STDS-802-3-EPOC] Link Ad Hoc Call at 11am All, We will have a call today at 11am. As I mentioned in last week's notes, I would like to have straw polls on the "green" items in the baseline proposal. I would also like to have additional discussion on the TDD PLC proposal that Nicola presented at the last meeting. Thanks, Ed... ------------------------------------------------------- Meeting information ------------------------------------------------------- Topic: EPoC Link Ad Hoc Date: Every Wednesday, from Wednesday, March 6, 2013 to Wednesday, September 25, 2013 Time: 11:00 am, Pacific Standard Time (San Francisco, GMT-08:00) Meeting Number: 929 603 864 Meeting Password: (This meeting does not require a password.) ------------------------------------------------------- To start or join the online meeting ------------------------------------------------------- Go to https://broadcom.webex.com/broadcom/j.php?ED=213819397&UID=497873612&RT=MiM0 ------------------------------------------------------- Audio conference information ------------------------------------------------------- 1. Provide your number when you join the meeting to receive a call back. Alternatively, you can call one of the following numbers: Broadcom US Dial-In: 1-949-926-6000 2. Follow the instructions that you hear on the phone. Cisco Unified MeetingPlace meeting ID: 929 603 864 Cisco Unified MeetingPlace profile number for meeting host: 11306251 ------------------------------------------------------- For assistance ------------------------------------------------------- 1. Go to https://broadcom.webex.com/broadcom/mc 2. On the left navigation bar, click "Support". To update this meeting to your calendar program (for example Microsoft Outlook), click this link: https://broadcom.webex.com/broadcom/j.php?ED=213819397&UID=497873612&ICS=MIU1&LD=1&RD=2&ST=1&SHA2=AAAAAti2/J7mTmtsjfoLcP7KmIiKmKxIPqL2R2-XAW0YqGM6 To check whether you have the appropriate players installed for UCF (Universal Communications Format) rich media files, go to https://broadcom.webex.com/broadcom/systemdiagnosis.php. http://www.webex.com IMPORTANT NOTICE: This WebEx service includes a feature that allows audio and any documents and other materials exchanged or viewed during the session to be recorded. You should inform all meeting attendees prior to recording if you intend to record the meeting. Please note that any such recordings may be subject to discovery in the event of litigation. [Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: cid:image009.jpg@01CD505E.7B800DB0] Edward Boyd | Sr Technical Director Broadcom Corporation | (O) 707-792-9008 | (M) 707-478-1146 [Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: image005]<http://www.linkedin.com/company/broadcom>[Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: image002]<http://twitter.com/#!/broadcom>[Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: image003]<https://www.facebook.com/Broadcom>[Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: image004]<https://plus.google.com/109188783526874806673/posts#109188783526874806673/posts>[Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: image006]<https://www.youtube.com/user/BroadcomCorporation>[Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: image008]<http://blog.broadcom.com/>[Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: image007]<http://broadcom.com/> ________________________________ <="" p=""> ________________________________________________________________________ To unsubscribe from the STDS-802-3-EPOC list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-3-EPOC&A=1
Attachment:
EPOC-Link-AdHoc-24APR13.pdf
Description: EPOC-Link-AdHoc-24APR13.pdf