Duane, 

 

Per discussion on the last Wednesday call, there seems to be a growing
concern that there might be long 0/1 runs in parity data, which will then
affect the signal on the wire. It is not so much of a problem when you have
short parity and RS codes are used, but it seems that LDPC might generate
long runs of 0s and 1s. 

 

I personally would like to see this verified, to make sure we're not putting
the scrambler in the wrong location. 

 

Marek

 

From: Duane Remein [mailto:Duane.Remein@xxxxxxxxxx] 
Sent: Friday, October 25, 2013 1:37 PM
To: STDS-802-3-EPOC@xxxxxxxxxxxxxxxxx
Subject: Re: [STDS-802-3-EPOC] Minutes and files posted for today's PHY
combined sub-group conference call

 

I have a question for the group at large. What is the need for the
scrambler/descrambler functions in line with the PHY-Link channels? Are
these necessary or are we just carrying these over from the optical PHY
where this would have a more obvious need? Would there be any significant
harm in eliminating this in the PHY-Link path?

Best Regards,

Duane

 

FutureWei Technologies Inc.

duane.remein@xxxxxxxxxx

Director, Access R&D

919 418 4741

Raleigh, NC

 

From: Mark Laubach [mailto:laubach@xxxxxxxxxxxx] 
Sent: Wednesday, October 23, 2013 3:13 PM
To: STDS-802-3-EPOC@xxxxxxxxxxxxxxxxx
Subject: [STDS-802-3-EPOC] Minutes and files posted for today's PHY combined
sub-group conference call

 

Greetings P802.3bn Task Force,

 

The minutes and presentation files from today's combined PHY conference call
are posted:

http://www.ieee802.org/3/bn/public/subtaskforce_phy/

 

Yours truly,

Mark Laubach, Chair

IEEE P802.3bn Task Force

 

Broadband Communications Group

Broadcom Corporation

1351 Redwood Way

Petaluma, CA, 94954