I have a question/comment concerning the rise time
definition discussed in today’s meeting. Would it be possible to define
the rise time as a maximum dV/dt? This would not require the use of different
percentage levels based on de-emphasis, and be immune to the voltage droop
experienced with a 5 zero 5 one type of situation. I could be way off base, but
it seemed reasonable. Merrick M. Moeller Signal Integrity Engineering Manager Cinch Connectors Inc. 630-693-2068 847-736-2919 mmoeller@xxxxxxxxx |