Hi all, I made some little modifications to my classification proposal in order to have 36 classes. In the attached document the modifications are in green This scheme uses 4 ping-pong cycles (fingers) but needs only 3 pins. I propose to define 9 sub-classes for each .af class and 9 classes in the new range from 12.95 to xx W. (36 classes total) Cycle One: Macro-Classes definition • Classes 1 to 3 cover .af power range o .af PSE classifies .at PD under 13W properly • Class 4 covers 12.95W to xx power range Cycle two: .at classification signature • .at PD sinks o class1 current if it’s a > 6.49W PD (classes 3 or 4 on Cycle1) o class4 current if it’s a <6.49W PD (classes 1 or 2 on Cycle2) • no potential false .at PD indication, because Cycle2 current is different from Cycle1) • Fixed current, no pin needed. Cycles three and four: class refining • Use only 3 classes: Class1 to Class3 to divide each class into 3 sub-classes (cycle 3) and each sub-class into 3 sub-sub-classes (cycle4). • No potential heating of the system • 4x3x3= 36 classes • No avoided class codes. • If the PSE doesn’t perform 4 class cycles, it is a .af PSE