Attached please find a slightly revised
presentation. We have clarified the explanation, better showing the dynamic
behavior and quantifying the test results. Also, after reviewing the detailed
UNH test report, there was an exceptional case for the 70% droop, (but none for
the 85% droop) so we decided to go with safety and recommend that the droop
specification produce waveforms identical to the existing 350uH specification
(87% long-term droop), without relaxing, even though the vast majority of PHYs
and cases would still work. -george |