Re: PD power start up
Dieter,
I vote for #2
Barry
_________________________________________________________________
Barry Male
Senior Principle IC Designer Internet: barry_male@xxxxxx
Power Management Products NH Phone: 603.429.8705
Texas Instruments CT Phone: 860.844.8183
7 Continental Blvd. NH FAX : 603.424.3460
Merrimack, NH 03054-0399 USA CT FAX : 860.844.8806
On Sat, 24 Mar 2001, Dieter Knollman wrote:
> Yair,
>
> I believe we have two choices.
>
> Choice 1: Define a special start up case for the PD.
> In this state the PD is allowed to violate steady state requirements.
> The PD may drop the line voltage to zero.
> The PD may draw any current level.
> The PSE will supply current at a level about 1.5 times the steady state
> value.
> The time for the start up state is limited to X ms.
>
> Choice 2: The PD meets steady state requirements.
> In order to receive power
> the PD input voltage is >30 volts and
> the PD current is >10ma and <350ma.
> Some violations are allowed for Y ms.
>
> Can we have a straw poll?
>