Re: Potential heating problem
Rick,
I'm not sure I agree with what you said.
Quote "where it stated:
PCB:
* CEI IEC 60603-7: current capacity for connectors @20 °C - 1.8 A (@ 0
°C
-2.2
A, @ 40 °C - 1.4 A, @ 60 °C - .75 A)
which implies that compliant patch panels will not have a problem with
350ma, "unquote
How does a connector spec that allows almost 10 times our requirement
(1.4A at 40 degreeC vs .175A at the same temperature) imply no problem?
Jack Andresen
Rick Brooks wrote:
>
> Part 1.1 Type: Plain Text (text/plain)
> Encoding: quoted-printable