[802.3af] Classification currents range




Guys,

It seems that the gaps between currents specified for various classes
of PDs during the classification procedure are too small and may produce
a measurement accuracy issue.


I am suggesting to change Table 3 in the Draft for the following numbers:
     Class0    <1.5mA
     Class1   8 - 10 ma
     Class2  13 - 16 ma
     Class3  19 - 23 ma
     Class4  27 - 33 ma
     Class5  37 - 45 ma
     Greater than 49mA: Invalid result, not a PD.

Comments?

Yair.