[802SEC] IEEE P802.3dd Maintenance #17: Power over Data Lines of Single Pair Ethernet PAR
- To: STDS-802-SEC@LISTSERV.IEEE.ORG
- Subject: [802SEC] IEEE P802.3dd Maintenance #17: Power over Data Lines of Single Pair Ethernet PAR
- From: "Law, David" <dlaw@HPE.COM>
- Date: Fri, 22 Jan 2021 18:23:04 +0000
- Accept-language: en-GB, en-US
- Arc-authentication-results: i=2; mx.google.com; dkim=pass header.i=@hpe.com header.s=pps0720 header.b=obK1C65d; arc=pass (i=1 spf=pass spfdomain=hpe.com dkim=pass dkdomain=hpe.com dmarc=pass fromdomain=hpe.com); spf=pass (google.com: domain of prvs=0656281c09=dlaw@hpe.com designates 148.163.143.35 as permitted sender) smtp.mailfrom="prvs=0656281c09=dlaw@hpe.com"
- Arc-authentication-results: i=1; mx.microsoft.com 1; spf=pass smtp.mailfrom=hpe.com; dmarc=pass action=none header.from=hpe.com; dkim=pass header.d=hpe.com; arc=none
- Arc-message-signature: i=2; a=rsa-sha256; c=relaxed/relaxed; d=google.com; s=arc-20160816; h=mime-version:content-transfer-encoding:content-language :accept-language:message-id:date:thread-index:thread-topic:subject :to:from:dkim-signature; bh=LiJyMlfQ1mM9WRJQAtjfXVmggWKElhisRK27kdZEqBQ=; b=VVXAGT9wRicozwzELteUeR0gvM99znwyOoHULBKXP09RIcTpnzM1K4JwQkS5NHyior O6QUE2vA9atBcLYnSo+uzb038lqLqk9Z1XbGMzdSlJ8PpfQLWxuUgq+f7eaMP/Zb6YVo jdyBsdu3qjDKGIArugUMUUv4aufenkWlkQ1YqkJuXTQPBG6U2xXE3Q8Slmc4RYxkkYwO VyyA1w7h0EaBDdVT05G+LHte3C8d8SxXh+tIyyeVawxaXJDGr6raPRHDPSEb/BlXSAHO YvnjOqIGbxxEAoUPxkPdFKlt2icwfTyW+USF8p4BL20jvf6PAWLaZFkmqygj41nQsezG RtEg==
- Arc-message-signature: i=1; a=rsa-sha256; c=relaxed/relaxed; d=microsoft.com; s=arcselector9901; h=From:Date:Subject:Message-ID:Content-Type:MIME-Version:X-MS-Exchange-SenderADCheck; bh=LiJyMlfQ1mM9WRJQAtjfXVmggWKElhisRK27kdZEqBQ=; b=lbVX8KmCWLaZzLxcWnu9Wya0AWEVfLKiSAqKyJeQIn7T9RJNpJbRK1vhKrBUdB3n8hPqngecTKDRrSqAyYN29+OkJ9aB0aNi3idt4ONfKrXd0IGsXd2sS/ATEkzP9d7vr4vJRgkpx8AA8f3GYbBmJrdIa1QGxSsIBxKrin3O+bmHSncbhfM1h6jSTFcSZl82GbHvVMdGS0xuMOk1VSBPx7S8/3ZIAczf4mjTd1mKExIPVAEJyaV2zoJ7WNb7PIrQZpSAPJd2ai9gai5B9NvHFi+QawC8SIR5mC+x7x+pm342eNWXeiJeEtYaviq0BlPukNOXaZIwTZm85MVM6hn4LQ==
- Arc-seal: i=2; a=rsa-sha256; t=1611339788; cv=pass; d=google.com; s=arc-20160816; b=ouJY+kxK4ZgA1eaIwTbt468YI0wqh+4mc4jj+6EEuarjNwrkJJUYPgynh+86SQBBUv nBxjeidA3mI8T7wXOg8Uglhz3v2cs0xDRdMByzuATc4n6Zkegn8kHpiXd/htiL2LlRRV lz6p2VzknZE21KPZ1unPv/jRQtLfla/8BuLK9l61oZqD3KhsigOQACnIH1EAKEkIYD4v WGIeqK6SxUUsvEMnx1yjzVLGLkoaTb6OMemJyW+D1LBPzFR3ZrBj25dsVrk3TlP4dUMe eApJ5Iy4BcEJSPQ/nxVDeP5GIAtuNZ4AdHlmV//p6W0oelWLxiKjjC1joiRR0cRyyLqi 2f4g==
- Arc-seal: i=1; a=rsa-sha256; s=arcselector9901; d=microsoft.com; cv=none; b=Uu1TzBMNhxVfhpyKaypp2NN92mezuBRYDldLQZ+/3MyFnQRiwL9LUFznqDC+qo7yePE7wxWhq86qXdffIiIKR3E43MeKrlPTnugzYagPDNUyNa0Qj7Wdx9WZ9eHya2CNAk3vHOKXKrsGbiPMzJG+B2pLVTs1sZbS+30TBZVC7ZRaKpsQuxoLSdpvPFYX4NKiowLFgl8+6hyTEz0m6EsriUqAh9wtmrSHM/Kb2PJsS9YgCeEXXedruTJLyWB8wHTBJjfTYM70w93wYoceba4FypBOmGoRzuZy/2MKzdekhYGFqt/cP7vm5cgY+b2Njhgo3H8/dovsylAdkS9nLJEGWA==
- Delivered-to: mhonarc@GROUPER.IEEE.ORG
- Delivered-to: stds-802-sec@listserv.ieee.org
- List-help: <https://listserv.ieee.org/cgi-bin/wa?LIST=STDS-802-SEC>, <mailto:LISTSERV@LISTSERV.IEEE.ORG?body=INFO%20STDS-802-SEC>
- List-owner: <mailto:STDS-802-SEC-request@LISTSERV.IEEE.ORG>
- List-subscribe: <mailto:STDS-802-SEC-subscribe-request@LISTSERV.IEEE.ORG>
- List-unsubscribe: <mailto:STDS-802-SEC-unsubscribe-request@LISTSERV.IEEE.ORG>
- Reply-to: "Law, David" <dlaw@HPE.COM>
- Sender: ***** IEEE 802 Executive Committee List ***** <STDS-802-SEC@LISTSERV.IEEE.ORG>
- Thread-index: Adbw6Ks9gHLA79ObS8meMsNhAO6LhA==
- Thread-topic: IEEE P802.3dd Maintenance #17: Power over Data Lines of Single Pair Ethernet PAR
Dear EC members,
In support of subclause 9.2 'IEEE 802 LMSC Approval' of the IEEE 802 Operations Manual, based on its '48 hour' rule provision, and the concurrence of the sponsor chair as required, please find below the required information in respect to the IEEE P802.3dd Maintenance #17: Power over Data Lines of Single Pair Ethernet PAR for consideration at the upcoming 2nd February 2021 IEEE 802 teleconference meeting.
Thanks and best regards,
David
[1] Draft PAR and CSD responses:
Draft PAR: <https://mentor.ieee.org/802-ec/dcn/21/ec-21-0012-00-00EC-ieee-p802-3dd-maintenance-17-draft-par.pdf>
CSD responses: Not required.
[2] Explanatory technical background material:
This project is to implement editorial and technical corrections, refinements, and clarifications to Clause 104, Power over Data Lines (PoDL) of Single-Pair Ethernet, and related portions of the standard. No new features will be added by this project.
[3] Status of the development of the PAR:
The draft PAR was approved (Y: 118, N: 0, A: 2) by the IEEE 802.3 Working Group at its interim meeting on Thursday 21st January 2021.
----------
This email is sent from the 802 Executive Committee email reflector. This list is maintained by Listserv.