Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

Re: [STDS-802-11-EDITORS] ANA values for TGbb



--- This message came from the IEEE 802.11 Editors' Reflector ---

Hello Volker,

 

Sorry for the delay. Here are your allocations:

TransactionID

Type

Status

User

Group

Resource

Ref Doc

Ref Subclause

Ref Location

Name

Req Value

Description

Allocated Value

1234

Allocate

Pending

Volker Jungnickel

TGbb

OperatingClassesGlobal

IEEE Std 802.11-2020

E.1

Table E-4

IR, 20 MHz spacing

150

1236

Allocate

Pending

Volker Jungnickel

TGbb

OperatingClassesGlobal

IEEE Std 802.11-2020

E.1

Table E-4

IR, 40 MHz spacing

151

1237

Allocate

Pending

Volker Jungnickel

TGbb

OperatingClassesGlobal

IEEE Std 802.11-2020

E.1

Table E-4

IR, 80 MHz spacing

152

1238

Allocate

Pending

Volker Jungnickel

TGbb

OperatingClassesGlobal

IEEE Std 802.11-2020

E.1

Table E-4

IR, 160 MHz spacing

153

 

 

I’m not sure what to do with “Reserved for near infrared” and have not allocated anything.

 

Presumably, you want room for contiguous expansion (maybe 320 MHz). To that end, I have allocated away from other allocations: 6 GHz goes to 136. 60 GHz has 180-187. And you have 150-153. Reserved values in between: 137-149, 153-179, 188-190.

 

BTW, I can mark a value as reserved for a specific future purpose. Should I do that for 154?

 

-Robert

 

 

From: Jungnickel, Volker <volker.jungnickel@xxxxxxxxxxxxxxxxx>
Sent: Monday, August 30, 2021 3:26 AM
To: Robert Stacey <rjstacey@xxxxxxxxx>; Stacey, Robert <robert.stacey@xxxxxxxxx>
Cc: nikola.serafimovski@xxxxxxxxxxxx
Subject: ANA values for TGbb

 

Dear Rober,

 

following a dicussion in TGbb, contained in CID 61 from Mark Hamilton in doc. 11-21/1050r3, could you, please, reserve 5 ANA values for TGbb? These ANA values are required for operation of LC with 20, 40, 80 160 and 320 MHz bandwidth (in the future). For your convenience, I include a snapshot of the related page 52 in TGbb D0.5.

 

Thanks and best regards – Volker

 

 

Prof. Dr. Volker Jungnickel

Metro-, Access and Inhouse Systems

Fraunhofer Heinrich Hertz Institut

Einsteinufer 37

10587 Berlin

Deutschland

Tel. 0162 255 2756

 


To unsubscribe from the STDS-802-11-EDITORS list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-EDITORS&A=1