Hi Vinod,
Thanks for the feedback. I think your comments makes sense. Since I am not sure if we can still deal with them with editorial change, I reassign
the CIDs to proper comment subgroup. Let me know if it works. Detailed responses are provided below. Best, Po-Kai Hi Po-Kai, Thanks for preparing the comment resolutions. Please find my comments below: For the CIDs 3326 and 3327: The description about ‘non-HT duplicate PPDU’ is a copy paste form the revmd document and they are not applicable to WUR PPDU formats. [Po-Kai]: I see. We probably want to remove the sentence. Not sure if this is editorial anymore. I will reassign these two CIDs to legacy portion comment group. For the CID 3021: the comment suggests to remove the repetition of T_{WUR-Sync} definition. As proposed resolution, I suggest to replace the sentence “TWUR-Sync
is the duration of WUR-Sync field,
TWUR-Sync=TWUR-sync-LDR
if low data rate is used to transmit the WUR-Data field of a WUR Basic PPDU, and
TWUR-Sync=TWUR-sync-HDR
if high data rate is used to transmit the WUR-Data field of a WUR Basic PPDU” with the following
“TWUR-Sync
is the duration of WUR-Sync field, as defined in Table 30-3 (Timing-related constants)” [Po-Kai]: Let me reassign this CID to Mathematical description of signals, and you can probably help us remove them with your suggestion.
J For the CID 3024: To address the concern of the commenter, I suggest to update the equation (31-11), using the TXTIME in equation (31-16). You can replace equation
(31-11) with the one below [Po-Kai]: Let me reassign this CID to Mathematical description of signals, and you can probably help us remove them with your suggestion.
J Thanks, Vinod
From: *** 802.11 TGba - WUR- Wake-up Radio Operation *** [mailto:STDS-802-11-TGBA@xxxxxxxx]
On Behalf Of Huang, Po-kai Dear all, I have prepared the CR documents for the 130 editorial comments. Please see the link below and let me know if you have further feedback. https://mentor.ieee.org/802.11/dcn/19/11-19-1025-00-00ba-cr-for-editorial-comments.xlsx Best, Po-Kai To unsubscribe from the STDS-802-11-TGBA list, click the following link:
https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBA&A=1 To unsubscribe from the STDS-802-11-TGBA list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBA&A=1 |