Re: [STDS-802-11-TGBE] 992 - mandatory/optional for MLO



Hi Laurent,

 

Thanks for initiating discussion about mandatory features related to MLO features.

 

I have a question related to slide 3 and SP#2. I agree with you about the list of sub features. But I think that the medium access procedure has to be defined for the MLO. At least, a discussion must conclude on how a multi-link transmission is initiated. If the conclusion is that standardized EDCA mechanism is used on each link, I am afraid that a multi-link transmission can never be started or the efficiency will be very low.

 

So for me, the medium access subject is a key point for the MLO.

 

Regards.

 

Patrice

 

From: Cariou, Laurent <laurent.cariou@xxxxxxxxx>
Sent: mercredi 19 août 2020 20:38
To: STDS-802-11-TGBE@xxxxxxxxxxxxxxxxx
Subject: [STDS-802-11-TGBE] 992 - mandatory/optional for MLO

 

Hi all,

Starting a thread for Q/A on doc 992 as we ran out of time.

Feel free to ask your questions there, and refer to the SP# to which the question applies.

 

Just posted below for reference the versions of SPs for SP1 discussed this morning:

  • Original SP
    • An EHT STA that is capable of operating in at least 2 bands shall be part of an MLD
  • Modified SP (Brian’s suggestion):
    • An EHT STA within a device capable of operating in at least 2 bands (or 2 channels within one band) shall be part of an MLD
  • Suggestion from Yong:
    • An EHT STA shall be part of an MLD?

 

Thanks,

Laurent