Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

Re: [STDS-802-11-TGBE] [EXT] RE: [STDS-802-11-TGBE] PDT-PHY-Data-field-Coding



Hi Yujin,

 

   Thank you for your comments. I will update the document after all MCS values are finalized. a_init = 3 is typo, it should be 4.

 

   For Nsd,short for 3x996, since it is 2x996+996, if we use the 3xNsd,short for 996 tone, then the last segment is much larger than the first 3 segments, while simply adding Nsd_short for 2x996 and Nsd,short for 996, it is much more balanced among 4 segments. That’s why I choose 732 instead of 720 as Nsd_short for 3x996. Also for other MRUs, we just simply summing up the Nsd,short for corresponding RUs.

 

Thanks

Yan

 

From: Yujin Noh <yujin.noh@xxxxxxxxxxxx>
Sent: Monday, August 31, 2020 1:34 PM
To: Yan(msi) Zhang <yan.zhang_5@xxxxxxx>; STDS-802-11-TGBE@xxxxxxxxxxxxxxxxx
Subject: [EXT] RE: [STDS-802-11-TGBE] PDT-PHY-Data-field-Coding

 

Caution: EXT Email

Hi Yan,

 

Thank you for sharing the draft.

Please find my comments in attached.

 

By the way, the link below is not correct.

 

Regards,

Yujin

 

From: Yan(msi) Zhang <yan.zhang_5@xxxxxxx>
Sent: Monday, August 31, 2020 11:02 AM
To: STDS-802-11-TGBE@xxxxxxxxxxxxxxxxx
Subject: [STDS-802-11-TGBE] PDT-PHY-Data-field-Coding

 

Dear Data field Coding TTT,

 

I have uploaded the draft for Data field Coding  to the server https://mentor.ieee.org/802.11/dcn/20/11-20-1339-01-00be-pdt-phy-mathematical-description-of-signals.docx. Please review it and give your feedback...

 

Thanks

Yan

 


To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1


To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1