Thread Links | Date Links | ||||
---|---|---|---|---|---|
Thread Prev | Thread Next | Thread Index | Date Prev | Date Next | Date Index |
Hi Yan, As for the Table, I missed the point you mentioned which is valid. Thank you for the clarification. By the way, a_init should be 3 in Eq. 34-3.11.5-11. What I intended was just to remove bracket in the Equation.
Removing mSTBC (in STBC is decided not to be supported in 11be), the bracket is not necessary anymore. Regards, Yujin From: Yan(msi) Zhang <yan.zhang_5@xxxxxxx> Hi Yujin, Thank you for your comments. I will update the document after all MCS values are finalized. a_init = 3 is typo, it should be 4. For Nsd,short for 3x996, since it is 2x996+996, if we use the 3xNsd,short for 996 tone, then the last segment is much larger than the first 3 segments, while simply adding Nsd_short for 2x996 and Nsd,short for 996, it is much more balanced
among 4 segments. That’s why I choose 732 instead of 720 as Nsd_short for 3x996. Also for other MRUs, we just simply summing up the Nsd,short for corresponding RUs.
Thanks Yan From: Yujin Noh <yujin.noh@xxxxxxxxxxxx>
Caution: EXT Email
Hi Yan, Thank you for sharing the draft. Please find my comments in attached. By the way, the link below is not correct. Regards, Yujin From: Yan(msi) Zhang <yan.zhang_5@xxxxxxx>
Dear Data field Coding TTT, I have uploaded the draft for Data field Coding to the server
https://mentor.ieee.org/802.11/dcn/20/11-20-1339-01-00be-pdt-phy-mathematical-description-of-signals.docx. Please review it and give your feedback..... Thanks Yan To unsubscribe from the STDS-802-11-TGBE list, click the following link:
https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1 To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1 |