Hi Ron, I don’t have the data handy but will try to dig out some. One example/assumption in my mind is channel 36 allow 17dBm for 20MHz pre-EHT, but a small RU can potentially be 20dBm. I will confirm this assumption and get back to you. BRs, Xiaogang. From: Ron Porat <000009a0da80e877-dmarc-request@xxxxxxxxxxxxxxxxx>
Hi Xiaogang, Thanks for reminding me the issue, so like you said at least part of it is now resolved or much better. As for transmitting small RU within 20Mhz preamble do you have some data? Thanks, Ron From: Chen, Xiaogang C [mailto:xiaogang.c.chen@xxxxxxxxx]
Hi Ron Please refer to the link below for the reason of allowing deboosting the pre-HE portion. Although the tone plan change improves the situation, deboosting may still be required for the case that pre-EHT is 20MHz and EHT is narrower (e.g.
2MHz) and the EHT TB PPDU is in the band edge. This is useful especially for the laptop STA that can transmit with higher power. https://mentor.ieee.org/802.11/dcn/19/11-19-0117-01-00ax-power-deboosting-pre-he.docx BRs, Xiaogang. From: Ron Porat <000009a0da80e877-dmarc-request@xxxxxxxxxxxxxxxxx>
Hi Yan, Thanks for the responses. On item 1) I’m forgetting the reason/need for it in 11ax, if it has to do with tone plan that was changed in 11be we may not need it. Suggest to discuss this a bit more explicitly then?
(meaning not sure we should include it even in yellow?) Thanks, Ron From: Yan(msi) Zhang [mailto:yan.zhang_5@xxxxxxx]
Hi Ron, Thanks for reviewing the draft.
Thanks Yan From: Ron Porat <ron.porat@xxxxxxxxxxxx>
Hi Yan, A few more comments:
Thanks, Ron From: Yan(msi) Zhang [mailto:yan.zhang_5@xxxxxxx]
Hi Sigurd, Tianyu, Alfred, Could you please add DCN 1337r2 to the PHY agenda? The link is https://mentor.ieee.org/802.11/dcn/20/11-20-1337-01-00be-pdt-phy-mathematical-description-of-signals.docx. Thanks Yan To unsubscribe from the STDS-802-11-TGBE list, click the following link: