Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

Re: [STDS-802-11-TGBE] SP text for 11-20/1322r1 (PHY Signaling Methodology for 11be Releases)



Hi Ross,

 

Thanks for the response.

 

Just to be clear, I copy part of Table 36-19 (U-SIG field of an EHT MU PPDU) in D0.1 below. Are you saying, in the row circled in the green box, change “Reserved and set to 1 (TBD)”  (in the Description field of the Table) to “Reserved for R2 features”, and change “Reserved (TBD)” to “Reserved”?

 

I am also fine with not saying anything to other reserved bits for now. We can made decision later.

 

 

 

 

 

 

Best regards,

Ray

 

From: Yujian (Ross Yu) <ross.yujian@xxxxxxxxxx>
Sent: Friday, October 16, 2020 3:33 AM
To: Rui Yang <Rui.Yang@xxxxxxxxxxxxxxxx>; Sameer Vermani <svverman@xxxxxxxxxxxxxxxx>; Bin Tian <btian@xxxxxxxxxxxxxxxx>
Cc: STDS-802-11-TGBE@xxxxxxxxxxxxxxxxx
Subject: 答复: SP text for 11-20/1322r1 (PHY Signaling Methodology for 11be Releases)

 

I remember, last time Bin suggested to focus on the Rx behavior when STAs read reserved bit that are not default values.

 

For the naming of the bit immediately after the "PPDU Type & Compression Mode" field is, I prefer to add a description saying reserved for R2 features. Reserved bit is ok for the naming.

 

For other bits, I think we don’t need to say anything.

 

regards

于健 Ross Jian Yu

Huawei Technologies

 

发件人: Rui Yang [mailto:Rui.Yang@xxxxxxxxxxxxxxxx]
发送时间: 20201015 23:33
收件人: Sameer Vermani <svverman@xxxxxxxxxxxxxxxx>; Yujian (Ross Yu) <ross.yujian@xxxxxxxxxx>; Bin Tian <btian@xxxxxxxxxxxxxxxx>
抄送: STDS-802-11-TGBE@xxxxxxxxxxxxxxxxx
主题: SP text for 11-20/1322r1 (PHY Signaling Methodology for 11be Releases)

 

Dear Sameer, Ross, Bin and All,

 

Per our discussion at the end of presentation of 11-20/1322r1 on Oct 12 (PHY ad hoc), I made the SP text below that hopefully captures all your comments and suggestions. Please let me know if you have any further comment and suggestion.  

 

Do you agree that

·       The bit immediately after the "PPDU Type & Compression Mode" field in the U-SIG of a MU-PPDU is reserved for indication of Release 2 features and is labeled as “Reserved for R2 features”?

o   The name of the 1-bit field is TBD

 

·       All other reserved bits in the U-SIG and EHT-SIG of a MU-PPDU are labeled or footnoted as "Reserved for additional R1 or R2 features"?

 

Best regards,

Ray

 


To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1