Hi Ruchen, Thanks for the response. We can discuss during your presentation. If needed, we can describe it in the first place where it shows up, e.g., U-SIG subclause. regards 于健
Ross Jian Yu Huawei Technologies 发件人: Ruchen Duan [mailto:r.duan@xxxxxxxxxxx]
Hi, Ross Thank you for the comment. I originally have the same thoughts, and that is how I compose Annex E for Draft 0.3. And I realize that the
Operating class should not be abused, so yes, it may not be proper to split. Then I feel that we shall find better place to define 320-1 and 320-2 other than Annex E, because we never define any BW (20/40/80/160 and 80+80) in Annex E. I think we can discuss during the PHY
meeting to find a proper location for this definition. Best, Ruchen From: Yujian (Ross Yu) [mailto:ross.yujian@xxxxxxxxxx]
Hi Ruchen, Can you clarify why we need two different operating class in Annex E for 320-1 and 320-2?
I think the comment just wants to have some description of what is 320-1 and what is 320-2. You can add some description, which is similar as in SFD. In addition to four entries for 20/40/80/160MHz, there exists two entries in U-SIG BW field for 320 MHz:
・
320-1 if PPDU channel center frequency is 31, 95, 159.
・
320-2 if PPDU channel center frequency is 63, 127, 191.
[Motion 135, #SP237, [48] and [80]] regards 于健
Ross Jian Yu Huawei Technologies 发件人: Ruchen Duan [mailto:r.duan@xxxxxxxxxxx]
Hi, Alfred, Sigurd and Tianyu Please add the following document to the PHY queue.
https://mentor.ieee.org/802.11/dcn/21/11-21-0424-00-00be-cr-for-36-3-22-and-annex-e.doc
Thank you and best, Ruchen To unsubscribe from the STDS-802-11-TGBE list, click the following link:
https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1 To unsubscribe from the STDS-802-11-TGBE list, click the following link:
https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1
To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1 |