Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

[STDS-802-11-TGBE] 答复: [STDS-802-11-TGBE] 答���: [STDS-802-11-TGBE] BFRP discussion



Hi Jinyoung,

 

Thanks. This helps people better understand that there may be multiple trigger frames within one TXOP, but each BFee can be only triggered once.

 

regards

于健 Ross Jian Yu

Huawei Technologies

 

发件人: 천진영 [mailto:jiny.chun@xxxxxxx]
发送时间: 2022118 12:36
收件人: Yujian (Ross Yu) <ross.yujian@xxxxxxxxxx>; STDS-802-11-TGBE@xxxxxxxxxxxxxxxxx
主题: RE: [STDS-802-11-TGBE] 答复: [STDS-802-11-TGBE] BFRP discussion

 

Hi Ross,

 

Thank you for your careful drawing.

The first BFRP is mandatory, but the second one is optional. So I slightly prefer the original one.

But Im okay with that because it just shows an example of sounding sequence.

Ill add the below figure in r3 and lets show members both of them in Joint CC.

 

Best regards,

Jinyoung

 

From: Yujian (Ross Yu) [mailto:00001792b51ef4ea-dmarc-request@xxxxxxxxxxxxxxxxx]
Sent: Monday, January 17, 2022 4:49 PM
To: STDS-802-11-TGBE@xxxxxxxxxxxxxxxxx
Subject: [STDS-802-11-TGBE]
: [STDS-802-11-TGBE] BFRP discussion

 

Hi Jinyoung,

 

For Figure 35-29, can we also have another example like below? The visio file is within the attached docx.

 

 

regards

于健 Ross Jian Yu

Huawei Technologies

 

发件人: 천진영 [mailto:jiny.chun@xxxxxxx]
发送时间: 2022113 9:00
收件人:
STDS-802-11-TGBE@xxxxxxxxxxxxxxxxx
主题: [STDS-802-11-TGBE] BFRP discussion

 

Hi,

 

Yesterday, Ive presented 21/2013 (CRs for 35.5.3) and members want more discussion by email. So I make this email thread.

The addressed issue is that:

Currently, the same STA cant be re-polled but the other STAs can be polled by additional BFRP Trigger in the same TXOP.

So the current figure has some problem.

So Id like to remove the word One or more sequences and make some changes the BFRP explanation as below.

BFRP Trigger frames sent within an EHT TB sounding sequence shall solicit EHT TB PPDUs. (move from other place)

An EHT beamformer that has initiated an EHT TB sounding sequence may send another more than one BFRP Trigger frame in the same TXOP as shown in Figure 35-29 (An illustration of EHT TB sounding).

 

Please give me your opinions or good directions for the CR.

 

Best regards,

Jinyoung


To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1


To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1


To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1