Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

[STDS-802-11-TGBE] Discussion on CID 17494



Hi, All,

 

I’ve presented CRs on 9.4.1.71 in Joint CC and the CID was deferred for more discussion.

Please let me know your opinion about the CID.

 

17494

Brian Hart

T

211.65

"(in case of MRU the lowest frequency stands for the lowest frequency of first RU and the highest frequency stands for the highest frequency of the last RU) " is actually very confusing. The Tables do not shed any light either.

If the first RU is lowest in freq and the last RU is highest in freq then this explanation unnecessarily and confusinglyu introduces RU numbering in an MRU - just have "(including for MRUs, noting that tones between RUs in an MRU are not fed back)". If the first/last RU is not necessarily lowest/highest in freq then, a) provide a xref to where this is are explained and b) rewrite this: "... second by the numbering of each RU in the MRU and third by data and pilot subcarrier index in each RU from the lowest freq to the highest freq ..."

Revised

 

Agree with the commenter, and the first suggestion seems good because the first RU is lowest in freq and the last RU is highest in freq (refer Table 36-5 (Data and pilot subcarrier indices for RUs).

 

To editor: Change the text in P211L65-P212L1

“(in case of MRU the lowest frequency stands for the lowest frequency of first RU and the highest frequency stands for the highest frequency of the last RU)”

to

“(including for MRUs, noting that tones between RUs in an MRU are not fed back)”

 

Best regards,

Jinyoung

 

From: Jinyoung Chun [mailto:jiny.chun@xxxxxxx]
Sent: Tuesday, March 14, 2023 8:45 PM
To: STDS-802-11-TGBE@xxxxxxxxxxxxxxxxx
Subject: Re: [STDS-802-11-TGBE] [EXT] [STDS-802-11-TGBE] Teleconference Agendas For Next Week: Uploaded

 

Hi Alfred,

 

Please add the following 3 CRs in the Queue.

-      11-23-0359-00-00be-lb271-cr-on-36.3.12.10 (PHY)

-      11-23-0365-00-00be-lb271-cr-on-9.4.1.70 (Joint)

-      11-23-0367-00-00be-lb271-cr-on-9.4.1.71 (Joint)

 

Best regards,

Jinyoung

 

From: Yan(MSI) Zhang [mailto:yan.zhang_5@xxxxxxx]
Sent: Tuesday, March 14, 2023 12:34 AM
To: STDS-802-11-TGBE@xxxxxxxxxxxxxxxxx
Subject: Re: [STDS-802-11-TGBE] [EXT] [STDS-802-11-TGBE] Teleconference Agendas For Next Week: Uploaded

 

Hi Alfred,

 

  Could you please add the following 2 CR documents to 11be PHY queue?

 

23/0422r0    11be lb271 CR for Clause 36.3.11 Mathematical description of signals    Yan Zhang (NXP Semiconductor)

23/0427r0    11be lb271 CR for clause 36.3.13.3 Coding  Yan Zhang (NXP Semiconductor)

 

Thanks

Yan

 

 

From: Alfred Asterjadhi <asterjadhi@xxxxxxxxx>
Sent: Saturday, March 4, 2023 7:36 AM
To: STDS-802-11-TGBE@xxxxxxxxxxxxxxxxx
Subject: [EXT] [STDS-802-11-TGBE] Teleconference Agendas For Next Week: Uploaded

 

Caution: EXT Email

Hello all,

 

I uploaded the telco agendas for the upcoming week.

- Mar 6                              Monday          – MAC/PHY                          19:00-21:00 ET

- Mar 8                              Wednesday    – Joint                                 10:00-12:00 ET

 

Link: https://mentor.ieee.org/802.11/dcn/23/11-23-0269-00-00be-jan-mar-tgbe-teleconference-agenda.docx

 

We will use these telcos to review and continue LB comment assignments.

 

Let me know if you have any questions. 

 

Regards,


Alfred

--

Alfred Asterjadhi, PhD

IEEE802.11 TGbe Chair,

Qualcomm Technologies Inc.

Cell #:    +1 858 263 9445

Office #: +1 858 658 5302


To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1


To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1


To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1


To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1