Hi Jinsoo,

I should say yes, according to what the group have discussed. If, in any case, you find other senarios may have more than one report and want to have a new discussion, I'm willing to help.  

BR,
Chaoming

 
发件人: Jinsoo Choi
发送时间: 2021-11-03 22:51
收件人: 'luochaoming@xxxxxxxx'; STDS-802-11-TGBF@xxxxxxxxxxxxxxxxx
主题: RE: [STDS-802-11-TGBF] 答复: [STDS-802-11-TGBF] TGbf meeting on November 1 (Monday) and 2 (Tuesday), 10:00am – 12:00pm ET

Hi Chaoming,

 

Thanks for your prompt answer. I got your point, so you assume there is no delayed report more than one instance right? Beyond it, it’s not the scope of your motion?

 

BR,

Jinsoo

 

From: luochaoming@xxxxxxxx [mailto:000015d97e832564-dmarc-request@xxxxxxxx]
Sent: Wednesday, November 3, 2021 6:26 PM
To: STDS-802-11-TGBF@xxxxxxxxxxxxxxxxx
Subject: Re: [STDS-802-11-TGBF]
: [STDS-802-11-TGBF] TGbf meeting on November 1 (Monday) and 2 (Tuesday), 10:00am – 12:00pm ET

 

Hi Jinsoo,

 

Thanks for your comments! I think this question has been discussed when I present 21/1438r0 in the Sept. Interim.  After that discussion, we changed the SP text to the current one which explicitly states for "multiple measurement setups". 

IMHO, the reason why we set this limitation is: for one single measurement setup, if it's delayed reporting,  if the measurement result of instance 1 would be reported in instance 2, and the measurement result of instance 2 would be reported in instance 3, and so on, that is to say the delay always happens, and it seems NOT possible to have measurement result of instance 1 and 2 both ready at the reporting phase of instance 2.

 

BR, 

Chaoming

发件人: Jinsoo Choi

发送时间: 2021-11-03 17:07

主题: RE: [STDS-802-11-TGBF] 答复: [STDS-802-11-TGBF] TGbf meeting on November 1 (Monday) and 2 (Tuesday), 10:00am – 12:00pm ET

Hi Chaoming,

 

Thanks for bring up the motion. I’m wondering whether the measurement results that will be sent by delayed reporting should be necessarily from multiple measurement setups or it could be also your target scenario to have the results from multiple measurement instances but by one single measurement setup since in this case the delayed feedback may be also useful.

 

You illustrates just the multiple measurement setups case and the SP was made accordingly, so it’s a bit confusing to me. Can you please elaborate your thought on that and see if some text clarification is needed?

 

BR,

Jinsoo   

 

From: luochaoming@xxxxxxxx [mailto:000015d97e832564-dmarc-request@xxxxxxxx]
Sent: Wednesday, November 3, 2021 5:34 PM
To: STDS-802-11-TGBF@xxxxxxxxxxxxxxxxx
Subject: Re: [STDS-802-11-TGBF]
: [STDS-802-11-TGBF] TGbf meeting on November 1 (Monday) and 2 (Tuesday), 10:00am – 12:00pm ET

 

Hi Tony,

 

I would like to submit 1 motion request as the following:

 

Motion 1

Do you agree to add the following into 11bf SFD ? 

  • In reporting phase, the measurement results from multiple measurement setups of a sensing responder may be included in a single measurement report frame for delayed reporting.
    • Support for obtaining more than one measurement results in a single measurement report frame sent by the responder is optional for the initiator.
    • Support for buffering more than one measurement result and sending it in a single measurement report frame to the initiator is optional for the responder.

Corresponding document  21/1438r1,  SP results: 16Yes, 5 No, 13 Abstain

 

BR,

Chaoming


 

发送时间: 2021-11-03 16:23

主题: 答复: [STDS-802-11-TGBF] TGbf meeting on November 1 (Monday) and 2 (Tuesday), 10:00am – 12:00pm ET

AddedJ

 

 

Best Regards : )

Tony Xiao Han

 

发件人: 장인선 [mailto:insun.jang@xxxxxxx]
发送时间: 2021113 15:14
收件人: STDS-802-11-TGBF@xxxxxxxxxxxxxxxxx
主题: Re: [STDS-802-11-TGBF] TGbf meeting on November 1 (Monday) and 2 (Tuesday), 10:00am 12:00pm ET

 

Hi Tony

 

Could you please add the following documents to the agenda?

- 1736r0, Role Negotiation in WLAN Sensing Procedure (Insun Jang (LG Electronics), 30min

- 1735r0, Procedure of Sensing Measurement Setup (Insun Jang (LG Electronics), 30min

(1736 would be the first)

 

Thanks

Best Regards

Insun

 

From: Hanxiao (Tony, WT Lab) [mailto:tony.hanxiao@xxxxxxxxxx]
Sent: Thursday, October 28, 2021 10:41 AM
To: STDS-802-11-TGBF@xxxxxxxxxxxxxxxxx
Subject: [STDS-802-11-TGBF] TGbf meeting on November 1 (Monday) and 2 (Tuesday), 10:00am
12:00pm ET

 

Dear all,

This is a reminder and call for submissions for the upcoming meeting on November 1 (Monday) and 2  (Tuesday), 10:00am 12:00pm ET. 

 

Please note:

1.      Please send the agenda request at least 24 hours prior to the call, following the format below:

     DCN, Title, Author (affiliation), Time duration

2.      I will cancel the call if there is no request received 24 hours prior to a call.

3.      Please upload your submissions (revision 0) on mentor 24 hours prior to the meeting so that members would have a chance to review those submissions offline. Otherwise,

a.      If there is not enough time during the meeting, the presentation will be delayed to the next meeting.

b.      If there is enough time during the meeting, the presentation will be moved to the end of the queue and be presented in the end. However, any related SP should be delayed to the next meeting.

4.      Please send the motion request around 10+5 days before the meeting (for teleconference, not for Plenary or Interim meeting), so that the TG chair could send the 10 day advance notice to the 802.11 reflector, after getting the approval from the WG chair.

5.      Dial-in information:

 

November 1 (Monday)

Join the Webex meeting here: https://ieeesa.webex.com/ieeesa/j.php?MTID=m752c22ca2bc5f3bc40542061cd924f75

Meeting number: 234 759 64188

Meeting password: wireless (94735377 from phones and video systems)

Join by phone: Tap to call in from a mobile device (attendees only) +1-408-418-9388 USA Toll
Global call-in numbers

Access code: 234 759 64188

Join from a video system or application Dial 23475964188@xxxxxxxxxxxxxxxx You can also dial 173.243.2.68 and enter your meeting number.

Join using Microsoft Lync or Microsoft Skype for Business Dial 23475964188.ieeesa@xxxxxxxxxxxxxx

Need help? Go to http://help.webex.com

 

November 2  (Tuesday)

Join the Webex meeting here: https://ieeesa.webex.com/ieeesa/j.php?MTID=m4d051bcccbd932e68816953f79f9bb23

Meeting number: 234 845 41802

Meeting password: wireless (94735377 from phones and video systems)

Join by phone: Tap to call in from a mobile device (attendees only) +1-408-418-9388 USA Toll
Global call-in numbers

Access code: 234 845 41802

Join from a video system or application Dial 23484541802@xxxxxxxxxxxxxxxx You can also dial 173.243.2.68 and enter your meeting number.

Join using Microsoft Lync or Microsoft Skype for Business Dial 23484541802.ieeesa@xxxxxxxxxxxxxx

Need help? Go to http://help.webex.com

 

Best Regards : )

Tony Xiao Han


To unsubscribe from the STDS-802-11-TGBF list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBF&A=1


To unsubscribe from the STDS-802-11-TGBF list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBF&A=1


To unsubscribe from the STDS-802-11-TGBF list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBF&A=1


OPPO

 

本电子邮件及其附件含有OPPO公司的保密信息,仅限于邮件指明的收件人使用(包含个人及群组)。禁止任何人在未经授权的情况下以任何形式使用。如果您错收了本邮件,请立即以电子邮件通知发件人并删除本邮件及其附件。

This e-mail and its attachments contain confidential information from OPPO, which is intended only for the person or entity whose address is listed above. Any use of the information contained herein in any way (including, but not limited to, total or partial disclosure, reproduction, or dissemination) by persons other than the intended recipient(s) is prohibited. If you receive this e-mail in error, please notify the sender by phone or email immediately and delete it!


To unsubscribe from the STDS-802-11-TGBF list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBF&A=1


To unsubscribe from the STDS-802-11-TGBF list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBF&A=1


To unsubscribe from the STDS-802-11-TGBF list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBF&A=1