Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

Re: [STDS-802-11-TGBF] LB276 CR for OST related editorial CIDs (23/1474, 23/1657)



Hi Tony

 

Please add 23/1657r0 to the presentation queue.

I’d like have it on OCT 12th slot.

 

Hi Ali

Thank you for your comment.

I think your understanding is same as Rojan(Commenter) and myself.

I added figure of Sensing NDPA, Sounding Trigger frame according to feedback provided from Rojan.

 

BR.

Atsushi.

 

From: stds-802-11-tgbf@xxxxxxxxxxxxxxxxx <stds-802-11-tgbf@xxxxxxxxxxxxxxxxx> On Behalf Of Ali Raissinia
Sent: Thursday, September 21, 2023 1:10 AM
To: Rojan Chitrakar <rojan.chitrakar@xxxxxxxxxx>; STDS-802-11-TGBF@xxxxxxxxxxxxxxxxx
Subject: RE: LB276 CR for OST related editorial CIDs
 (23/1474, 23/1657)

 

If I understand option 2 correctly, the Measurement Session Indication field will continue to be used as an octet in which 3 bits of it would be Measurement Session ID field. If that is the case, then I also like option 2.

 

From: Rojan Chitrakar <00002005fb56ded7-dmarc-request@xxxxxxxxxxxxxxxxx>
Sent: Tuesday, September 19, 2023 5:38 PM
To: STDS-802-11-TGBF@xxxxxxxxxxxxxxxxx
Subject: Re: [STDS-802-11-TGBF] LB276 CR for OST related editorial CIDs
 (23/1474, 23/1657)

 

WARNING: This email originated from outside of Qualcomm. Please be wary of any links or attachments, and do not enable macros.

Hi Atsushi,

 

Thanks for resolving these. For CID 3068, 3 bits are used for Measurement Session ID in Sensing NDPA, Sounding Trigger frame etc., so option 2 seems to be the right option for me.

 

Best Regards,

Rojan Chitrakar

 

From: stds-802-11-tgbf@xxxxxxxxxxxxxxxxx <stds-802-11-tgbf@xxxxxxxxxxxxxxxxx> On Behalf Of SHIRAKAWA Atsushi
Sent: Tuesday, September 19, 2023 7:03 PM
To: STDS-802-11-TGBF@xxxxxxxxxxxxxxxxx
Cc: SHIRAKAWA Atsushi <shirakawa.atsushi@xxxxxxxxxxx>
Subject: LB276 CR for OST related editorial CIDs
 (23/1474, 23/1657)

 

Hi All

 

I presented 23/1477r0 in last Interim session and got advice that the Resolution Column should be modified according to Comment Resolution Guidance.

I modified it as 23/1474r1 attached and moved sensitive CID3068 to another document 23/1657r0.

 

I understood CID3068 is a sensitive issue and listen to a more broader opinion.

Please go through 23/1657 and comment back.

 

BR.

Atsushi.

 


To unsubscribe from the STDS-802-11-TGBF list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBF&A=1


To unsubscribe from the STDS-802-11-TGBF list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBF&A=1


To unsubscribe from the STDS-802-11-TGBF list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBF&A=1


To unsubscribe from the STDS-802-11-TGBF list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBF&A=1

Attachment: 11-23-1657-00-00bf-LB276-CR-for-OST-CID3068_r2.docx
Description: 11-23-1657-00-00bf-LB276-CR-for-OST-CID3068_r2.docx