Hi Alfred,

 

Could you please update my one of SPs below?

 

SP#4: Do you agree to include the following into the 11bn SFD?

  • In response to BSRP Trigger frame transmitted by a non-AP STA, an AP transmits a Multi-STA BlockAck frame

        Block Ack Starting Sequence Control subfield and Block Ack Bitmap subfield are not present if there is no any feedback information

        Values of Ack Type and TID are TBD

Supporting documents: [24/1464]

 

Best Regards,

Hongwon

 

From: hongwon.lee <hongwon.lee@xxxxxxx>
Sent: Wednesday, January 8, 2025 4:06 PM
To: 'STDS-802-11-TGBN@xxxxxxxxxxxxxxxxx' <STDS-802-11-TGBN@xxxxxxxxxxxxxxxxx>
Subject: [STDS-802-11-TGBN] TGbn MAC Queue request

 

Hi Alfred,

 

Happy New Year!!!

 

Could you please add the following contribution to the MAC Queue?

  • [Control] 11-25/0062r0 More Consideration for feedback information     Hongwon Lee(LG Electronics)

 

Could you also please add the following SPs to the MAC Queue?

 

SP#1: Do you agree to include the following into the 11bn SFD?

  • A TXOP holder transmitting a BSRP Trigger frame as an ICF which is addressed to at least a UHR STA that enabled a dynamic unavailability operation mode, shall ensure that UL Length sets to a sufficient length for PPDU that contains a Multi-STA BA as an ICR including unavailability information

Supporting documents: [24/1464]

 

SP#2: Do you agree to include the following into the 11bn SFD?

  • When a STA intends to indicate unavailability in a BSRP Trigger frame as an initial control frame (ICF), the unavailability consists of:

        Unavailability Target Start Time field that indicate the start time in TSF when the STA becomes unavailable and uses 9 bits with a granularity of 64us, and

        Unavailability Duration field that indicates the time during which the STA is unavailable and uses 9 bits with a granularity of 64us

 Supporting documents: [24/1464]

 

SP#3: Do you agree to include the following into the 11bn SFD?

  • When a STA intends to indicate unavailability in a BSRP Trigger frame as an initial control frame (ICF), the unavailability is indicated in a Special User Info field with an AID

        The AID is TBD (but not 2007)

 Supporting documents: [24/1464]

 

SP#4: Do you agree to include the following into the 11bn SFD?

  • In response to BSRP Trigger frame transmitted by a non-AP STA, an AP transmits a Multi-STA BlockAck frame in which Block Ack Starting Sequence Control subfield and Block Ack Bitmap subfield are not present

        Values of Ack Type and TID are TBD

Supporting documents: [24/1464]

 

Best Regards,