Hi Alfred,

Please add the following 2 passed SPs to the motion queue (PHY CoBF).

•         Move to add the following to the 11bn SFD

–        The CoBF Sync frame carries the following information

•         How to indicate the information is TBD

Category

Control

‘CoBF Sync’

PHY Common Info

Length

PHY Version Identifier

Bandwidth

Punctured Channel Information

BSS Color 1, BSS Color 2

TXOP

Number of UHR-SIG Symbols

GI+LTF Size

Number Of UHR-LTF Symbols

Number of CoBF Users

Per-User Info in Both BSS

STA ID

BSS Color Indication

MCS

Spatial Configuration

2xLDPC

 

–        Supporting doc: 11-25/389r0, 11-25/399r0, 11-25/401r0

Passed unanimously 


•         Move to add the following to the 11bn SFD

–        In each of the CoBF Invite, Response and Sync frames, if there is information for more than one users, the users are ordered according to Nss in non-increasing order

•         The order of users in the sharing BSS in the Sync frame is aligned with that in the Invite frame.

•         The order of users in the shared BSS in the Sync frame is aligned with that in the Response frame.

–        Supporting doc: 11-25/389r0, 11-25/381r0, 11-25/397r0

Passed unanimously


Thanks,
Alice


On Tue, Mar 11, 2025 at 11:56 AM Ron Porat <000009a0da80e877-dmarc-request@xxxxxxxxxxxxxxxxx> wrote:

Hi Alfred,

 

Please also add the following SP to the motion queue (PHY COBF)

 

Move to add the following in the 802.11bn SFD:

Joint/cross-BSS sounding feedback is limited to UL OFDMA if >1 STA is sounded

 

Passed unanimously

 

Thanks,

Ron

 

 

 

From: Sameer Vermani <000039a3734fa32e-dmarc-request@xxxxxxxxxxxxxxxxx>
Sent: Tuesday, March 11, 2025 9:38 AM
To: STDS-802-11-TGBN@xxxxxxxxxxxxxxxxx
Subject: Re: [STDS-802-11-TGBN] Motions Requested for COBF

 

Hi Alfred,

 

Please also add the following 3 to the motions queue (all based on document 11-25/0381r0)

 

  1. Move to add the following in the 802.11bn SFD:
    • The COBF PPDU’s GI+LTF support and signaling is as follows:
      • Support of following GI+LTF combinations to be mandatory at both AP and STA
        • 2x LTF +0.8us, 2xLTF+1.6us, 4xLTF+3.2us
      • Additionally, 2x LTF+0.8us GI usage for a COBF pair is exchanged at the group formation stage
        • Each AP conveys if it can use 2x+0.8us GI for this COBF group or not
        • No further last-minute negotiation before COBF transmission
      • Invite frame from sharing AP dictates the LTF+GI combination keeping the shared AP’s ability to use 2x LTF+0.8us in mind

 

Results of SP were  41Y/12N/32A

 

  1. Move to add the following in the 802.11bn SFD:
    • BSS ordering of per-user SIG fields in the preamble of a COBF transmission
      • In the cases where the user fields of either BSS may go first while preserving the Nss in non-increasing order, the user fields of the sharing BSS go first

 

Passed unanimously

 

  1. Move to add the following in the 802.11bn SFD:

There shall be a frame-exchange before the COBF sounding between the two APs which will at-least serve the following goals:

    • Unavailability/decline indication from the responding AP
      • Used by responding AP to refuse participation in a COBF sounding process
    • Exchange of sounding Nss capability of the STAs being sounded in the two BSSs
      • The minimum sounding Nss capability of the participating STAs in each BSS will be exchanged
    • Note: Design of the frames is TBD by MAC group

 

Passed unanimously

 

 

Regards,

Sameer

 

 

From: Sameer Vermani
Sent: Monday, March 10, 2025 6:36 AM
To: asterjadhi@xxxxxxxxx; STDS-802-11-TGBN@xxxxxxxxxxxxxxxxx
Subject: Motions Requested for COBF

 

Hi Alfred,

Please add the following PHY motions (all reached consensus in PHY adhoc without any objections based on document 11-25/0083r1) to the motions queue:

  1. Move to add the following to the 802.11bn SFD

•         802.11bn defines the concept of a sync-reference AP and a sync-follower AP for CFO correction in COBF

•         Sync-follower AP pre-corrections needed

•         For sequential sounding:

•       All the NDPs sent by it during sounding phase that are sent for the purpose of sounding the STAs in the other BSS (Mandatory)

•       For the NDPs sent by it for sounding the STAs in its own BSS, it is recommended but not mandatory that the sync follower AP pre-correct those NDPs

•         For joint sounding

•       All the NDPs sent by it during the sounding phase (Mandatory)

•         The COBF sync and COBF PPDU during transmission phase using the same frequency pre-correction value as the sounding phase, when it is the sharing AP

•         Sync-reference AP does not pre-correct during transmission phase when it is the sharing AP

 

  1. Move to add the following to the 802.11bn SFD

•         The sync-follower AP shall use the NDPA frame sent by the sync-reference AP to pre-correct the NDP frequency to be within a TBD range (e.g., 350Hz) of the sync-reference AP’s frequency

•         Applies to sequential and joint sounding

•         The pre-correction of cross-BSS NDP and joint NDP is mandatory

•         The pre-correction of in-BSS NDPs is recommended but not a mandatory requirement

 

  1. Move to add the following to the 802.11bn SFD

•         The sharing AP is the AP that transmits the final sync frame before the COBF PPDU

•         Regardless of who is the sync-reference

•         Note: This ensures a consistent protocol and a consistent behavior at sharing AP

 

  1. Move to add the following to the 802.11bn SFD

•         The shared AP always pre-corrects COBF PPDU based on the final sync

•         To bring the two APs within a TBD frequency range of each other (e.g., ~350Hz)

•         Note: Regardless of which AP is the sync-reference, this ensures consistent behavior at shared AP

 

Thanks,

Sameer

 

 

 