Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

Re: [STDS-802-16] T16 Clarification



Title:
Phillip Barber wrote:
Also, Figure 95 is hardly compelling either. It merely shows that CID must have a common QoS Parameter Set, which makes sense since bandwidth requests are made based on CID, not SFID.
 
Provided that the object model diagram (figure 95) is not just informational, it clearly states that a Connection can be linked to 1 and only 1 Service Flow (specified by the little 1 in the left shadow of the Service Flow box).

With your interpretation, the diagram would show a N like for the relation between MAC PDUs and Service Flow.

What do you think ?

Best regards,

Joël Demarty
SEQUANS Communications
101-103 Bd McDonald, 75019 Paris
+33 (0)1 4489 4826 Tel.
+33 (0)1 4489 4806 Fax
+33 (0)6 6063 5720 Cell
joel@sequans.com
www.sequans.com