[STDS-802-16] Regarding Overlapping Pilots
- To: STDS-802-16@listserv.ieee.org
- Subject: [STDS-802-16] Regarding Overlapping Pilots
- From: varma indukuri <varma.ivs@gmail.com>
- Date: Fri, 29 Oct 2004 11:08:44 +0530
- DomainKey-Signature: a=rsa-sha1; q=dns; c=nofws; s=beta; d=gmail.com; h=received:message-id:date:from:reply-to:to:subject:mime-version:content-type:content-transfer-encoding; b=RDGo5Ev9l9cMujFiBCkB4rRsck7+u2UiiJxqLmjSJ2QrlB6nJ10BVsA58Sz1yNVd6S8FVkZhzVhNAjnFh0O4B0A1y+PLy4SP2WPXRWc8fenbJTEzHvbT2EPwZBNqgdBTjS8sIR9lLDy9h+gpyHIIyUTRi5GtoGGqOtxCgtc0M9Q=
- Reply-To: varma indukuri <varma.ivs@gmail.com>
- Sender: owner-stds-802-16@listserv.ieee.org
hi all
I am seeing the same problem in 16e also for the "1024-FFT OFDMA
downlink carrier allocations - FUSC". Table 309a from "802.16e/D5"
standard.
The variable pilots at the locations 324,336,516,520 are overlaping
with 330,342,522,526 constant pilots. Perhaps I am mistaken.Plz
intimate me if you find some solution for this
Regards,