Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

Re: [10GBT] THP coefficient set clarification & robustness



Glenn - those are only useful for magnitude information.  How did you
scale the phase information?

-----Original Message-----
From: IEEE P802.3an Reflector [mailto:stds-802-3-10gbt@ieee.org] On
Behalf Of Glenn Golden
Sent: Monday, January 10, 2005 9:34 AM
To: STDS-802-3-10GBT@LISTSERV.IEEE.ORG
Subject: Re: [10GBT] THP coefficient set clarification & robustness

Eric Wang writes:
>
> I am trying to repeat your results in golden_1_1104. So I just
> wonder how you scaled the 100m data to different lengths <100m.
Thanks.
>

Hi Eric,

It was scaled in accordance with the procedures in the channel models
section of Clause 55. In the copy that I have (old) the subsection
title is "Insertion Loss Scaling".

Glenn