RE: Clause 51 (XSBI) LVDS spec




Tord,

If there is a deviation that we want to allow, we will need to specify 
it. Common mode output voltage tolerance shouldn't be an issue if we
agree that the interface is AC coupled. Were there other problems?

Pat



-----Original Message-----
From: Haulin Tord [mailto:tord.haulin@xxxxxxxxxxxxx]
Sent: Friday, October 20, 2000 6:34 AM
To: 'Jscquake@xxxxxxx'
Cc: stds-802-3-hssg@xxxxxxxx
Subject: Clause 51 (XSBI) LVDS spec


Justin Chang:
The IEEE 1596.3 LVDS spec has a few parameter specifications that very
many LVDS circuits do not follow in detail, e.g. the unloaded common mode
output voltage tolerance of 1200mV +/-75mV. 

Can the electrical specs in clause 51 referring to  IEEE 1596.3 be assumed
to
also inherit the generally accepted deviations?

Best regards
Tord Haulin

================================================================
Optillion
Tord Haulin                                           Ph:   +46  8-477-4192
Kronborgsgrand 9                           Cellular:    +4670-181-5231
S-164 87 Kista                                    Fax:    +46  8-477-4151
SWEDEN
http://www.optillion.com         mailto:Tord.Haulin@xxxxxxxxxxxxx