Re: Clause 51 (XSBI) LVDS spec
Hello Tord,
Yes, there are many vendors that do not necessarily follow the IEEE specs and
yes, we need to have the "tolerance" for these parameters.
Pat,
I do not think that we want to limit the restrictions of the LVDS interface to
AC coupling. This would be horrendous from a component point of view.
Justin
In a message dated 10/20/00 12:39:05 PM Pacific Daylight Time,
pat_thaler@xxxxxxxxxxx writes:
> Tord,
>
> If there is a deviation that we want to allow, we will need to specify
> it. Common mode output voltage tolerance shouldn't be an issue if we
> agree that the interface is AC coupled. Were there other problems?
>
> Pat
>
>
Justin Chang
Quake Technologies, Inc.
50 Airport Parkway, San Jose, CA. 95110
Tel: 408-437-7723 email: justin@xxxxxxxxxxxxx
Fax: 408-437-4923 internet: www.quaketech.com