Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

[802.3ae] Clause 48 state machines



Rich,
	I just noticed this, and its too late for a comment.  If I am not
mistaken, the hex values assigned in the statemachines are not correct. 
Notice in the RX state machine state LOCAL_FAULT_INDCATE <= 0h9c000001. 
It should be 0100009c  because lane zero is bits 7:0.

If no one has commented on this, and you agree it is a problem can you
sponsor the comment?

Thanks,

justin


-- 
Justin Gaither                           Phone: 512-306-7292  x529
Xilinx, Communications Technology Div.   Fax:   512-306-7293
500 N. Capital of TX Hwy.
Bldg 3                         email: justin.gaither@xxxxxxxxxx
Austin, TX 78746               WWW:   www.rocketchips.com
                                      www.xilinx.com
begin:vcard 
n:Gaither;Justin
tel;fax:512-306-7293
tel;work:512-306-7292 x529
x-mozilla-html:TRUE
org:Xilinx;Communication Technology Division
version:2.1
email;internet:justin.gaither@xxxxxxxxxx
title:Sr. Staff Engineer
adr;quoted-printable:;;500 N. Capital of TX Hwy=0D=0ABldg 3;Austin;TX;78746;
x-mozilla-cpt:;-3520
fn:Justin Gaither
end:vcard