Hi Frank,
Thank you for confirmation.
Ragnar
From: "Frank Wang (王順生)" <frank.wang@xxxxxxxxxxx> Date: Tue, Nov 11, 2025, 7:06 PM To: "Jonsson Ragnar (ATV ES DB DSP)" <Ragnar.Jonsson@xxxxxxxxxxxx>, STDS-802-3-ISAAC@xxxxxxxxxxxxxxxxx Subject: RE: Questions on new TDD PHY Control State Diagram presentation
Hi Ragnar,
Thank you again for your detail review. For the variable “config”, it was my mistake while I redrew the state diagram. I also agree with you that “_down” should be “_done”. I will update another version for the correction.
Regards, Frank
From: Ragnar Jonsson <Ragnar.Jonsson@xxxxxxxxxxxx>
Hi Ching-Yen, Frank, and Wei,
I have a question regarding your presentation: https://www.ieee802.org/3/dm/public/1125/Lee_etal_3dm_01a_1125.pdf
In the “Updated TDD PHY Control State Diagram” on slide 4, the transition criteria out of the COUNTDOWN0 and COUNTDOWN1 states are given as config = (MASTER * loc_countdown0_down) + (SLAVE * rem_countdown0_down)
This text does not appear to be consistent with the conventional use of the “config” variable, including the transition criteria out of the SILENT state. I assume that the criteria are meant to be ((config=MASTER) * loc_countdown0_down) + ((config=SLAVE) * rem_countdown0_down)
Can you please confirm that my understanding is correct?
I also wonder if “loc_countdown0_down” should be named “loc_countdown0_done”, for consistency with other variables like “minwait_timer_done”.
Ragnar