Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

Re: [802.3_ISAAC] withdraw comment 105



Hi Ragnar,

Thanks for letting me know.  I'll update this comment to "Withdrawn" in the database and won't make the comment #105 change shown in https://www.ieee802.org/3/dm/public/0326/Markup%20of%20Figure%20201-22%2003042026V3.pdf when I update Figure 201-22 for D0.c.

Natalie Wienckowski
In-Vehicle Networking Solutions LLC
natalie@xxxxxxxxxxxxxxxxxxx
586-247-0846


On Fri, Mar 6, 2026 at 2:39 PM <Ragnar.Jonsson@xxxxxxxxxxxx> wrote:

Hi Natalie,,

 

 

I want to withdraw comment 105:

 

105

Jonsson, Ragnar

Infineon

201

201.5.2.8.2

116

22

E

The statement "loc_countdown_done This variable is set to FALSE when the PHY Control state diagram is in the DISABLE_TRANSMITTER state" should be reflected in Figure 201-22

Update DISABLE_TRANSMITTER state in Figure 201-22 to include "loc_countdown_done<=FALSE"

ACCEPT IN PRINCIPLE.



Update Figure 201-22 per "Markup of Figure 201-22 03042026V3.pdf".

PHY Cntrl

 

 

The reason is that this is already accounted for in the definition of loc_countdown_done (p 116, L20), where it is stated that loc_coundown_done is set to FALSE in the DISABLE_TRANSMIT state.

 

 

Ragnar


To unsubscribe from the STDS-802-3-ISAAC list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-3-ISAAC&A=1