Thread Links | Date Links | ||||
---|---|---|---|---|---|
Thread Prev | Thread Next | Thread Index | Date Prev | Date Next | Date Index |
All – as promised, I have gone through and checked the presentaiton on noise, and I have made clarifications and corrections. Some of the levels have been slightly adjusted, and I found that there were wrong titles and a couple wrong graphs
pasted in. The worst-case source remains an AWGN source at -112.9 dBm/Hz -10log10(fbaud/75 MHz) dBm/Hz, but I left out that it represents primarily the AFEXT from a near 100BASE-T1L signal. I’ve also adjusted the levels of the mixed crosstalk source based
on measurements compared with the computed values. The spreadsheet with the noise PSDs has been uploaded as well. I will process the minutes over the next few days and get them posted too. -george George Zimmerman, Ph.D. President & Principal CME Consulting, Inc. Experts in Advanced PHYsical Communications 310-920-3860 To unsubscribe from the STDS-802-3-SPEP2P list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-3-SPEP2P&A=1 |