Re: [STDS-802-3-EPOC] Updated PMD Outline Proposal
Thank you, Joe,
Such a clarification statement ought to be included in your presentation
outline. As for a reader of an Ethernet standard, when I see a word "frame"
my first tendency is to interpret that as a MAC frame, rather than LDPC
frame.
Probably, the more proper term might be "FEC frame" or something in the
lines of. I am sure on the call we can come up with 30 ways to name it right
J
Regards
Marek
From: Solomon, Joe [mailto:Joe_Solomon@xxxxxxxxxxxxxxxxx]
Sent: Tuesday, 25 June 2013 4:06 PM
To: STDS-802-3-EPOC@xxxxxxxxxxxxxxxxx
Subject: Re: [STDS-802-3-EPOC] Updated PMD Outline Proposal
The frame we are referring to is the "LDPC frame" - the block of LDPC bits.
Maybe frame is the wrong term. It's related to the frame error rate referred
to in the project objectives, but is to specify the performance of the
receiver at the PMD layer.
We can discuss on the call tomorrow to improve the terminology.
Thanks for the question!
From: Marek Hajduczenia [mailto:marek.hajduczenia@xxxxxx]
Sent: Saturday, June 22, 2013 1:32 PM
To: Solomon, Joe; STDS-802-3-EPOC@xxxxxxxxxxxxxxxxx
Subject: RE: [STDS-802-3-EPOC] Updated PMD Outline Proposal
Hi Joe,
A quick question on page 11 - you're listing here "100.2.7.2 Frame Error
Rate" and I wonder what "frame" you really mean - is this OFDM frame or
Ethernet frame? In either case, clarification is warranted, since at this
level Ethernet frames are rather hard to delineate with all the encoding on
top of them .
Marek
From: Solomon, Joe [mailto:Joe_Solomon@xxxxxxxxxxxxxxxxx]
Sent: Friday, June 21, 2013 11:46 AM
To: STDS-802-3-EPOC@xxxxxxxxxxxxxxxxx
Subject: [STDS-802-3-EPOC] Updated PMD Outline Proposal
Team,
Please find attached an updated PMD outline; we will be reviewing this
presentation during the "pre-socialization" meeting next week (Wednesday, 10
ET).
Joe Solomon
Comcast - T & P Access Technology
303-242-7037
cid:image001.png@01CDE9BB.95EA0330
_____
<="" p="">
_____
________________________________________________________________________
To unsubscribe from the STDS-802-3-EPOC list, click the following link:
https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-3-EPOC&A=1