Thread Links | Date Links | ||||
---|---|---|---|---|---|
Thread Prev | Thread Next | Thread Index | Date Prev | Date Next | Date Index |
Hi Steve, The meeting right now is addressing the questions
we have to the ISO/IEC committee. Regarding the validity of Jo's work I have
also noticed this point and as I mentioned earlier his work requires further
review since few things there obviously not reflecting our
system behavior. I'll review it in details and we will discuss more on it. Yair From:
owner-stds-802-3-poep@xxxxxxxx [mailto:owner-stds-802-3-poep@xxxxxxxx] On Behalf Of Regarding the issue of cable heating, I have a concern about Jo
Wallings analysis. In his supporting document,
"walling_2_0905.pdf" the last sentence in the second paragraph states
"...under the assumption that all pairs in all cables are energized with
the same current." This is a valid assumption for PoE Plus,
since it appears very likely that we'll use a 4-pair system.
But Jo's assumption is invalid for 802.3af since only half of the pairs
are carrying current. So I think Jo overestimated the heat
dissipation in the cables (for 802.3af) by a factor of 2. |