[802.3af] comment #323



Colleagues: I am having a hard time word-smithing the correct text for this comment.  I don’t think Geoff’s response does a significantly better job of clarifying than the original text.  Please submit some possible changes to the text to resolve this comment.  Thanks.

 

-----------

CommentID:  323

CommenterName:  Thompson, Geoff

CommenterEmail:  thompson@xxxxxxxx

CommenterPhone:  408 495 1339

CommenterFax: 

CommenterCo:  Nortel Networks

Clause:  33

Subclause:  33.2.1.3

Page:  39

Line:  3

CommentType:  E

 

Comment: 

The text:  "A PSE device may provide power via one of two valid four-wire connections. In each four-wire connection, the two wires associated with a pair carry the same nominal current in each conductor."

does not specifically differentiate between a phantom circuit and two unbalanced circuits. I would prefer that the text more specifically denote our use of a phantom circuit.

CommentEnd: 

 

SuggestedRemedy: 

How about:

"A PSE device may provide power via one of two valid four-wire connections. In each four-wire connection, the two conductors associated with a pair each carry the same nominal current in both magnitude and polarity."

...or I am open to suggestion.

RemedyEnd: 

 

Response: 

 

ResponseEnd: 

CommentStatus:  X

ResponseStatus:  O

Topic: 

CreateDate:  1/3/2003

LastModDate:  1/3/2003

DispatchDate: 

WrittenDate: 

Accept_RejectDate: 

Closed_UnsatisfDate: 

VoterStatus:

 

Chad Jones                                    cmjones@xxxxxxxxx

Hardware Engineer                        Phone: 330-664-7818

WNBU Engineering                        Fax: 330-664-7990

Cisco Systems

320 Springside Drive

Suite 350

Akron, OH 44333-4500                  www.cisco.com