Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

Re: [STDS-802-11-TGBE] PDT-MAC-MLO: General and Multi-link setup: Procedure



 

 


From: Rojan Chitrakar [mailto:rojan.chitrakar@xxxxxxxxxxxxxxxx]
Sent: Thursday, September 10, 2020 12:27 AM
To: STDS-802-11-TGBE@xxxxxxxxxxxxxxxxx
Subject: Re: [STDS-802-11-TGBE] PDT-MAC-MLO: General and Multi-link setup: Procedure

 

Hi Po-kai,

 

As we discussed in yesterday’s call, it will be good to have a definition for MLD association similar to what we have for association:

 

association: (#2222)The service used to establish an access point (AP) or personal basic service set (PBSS)

control point (PCP), and a station (STA) and enable STA invocation of the distribution system services

(DSSs).

[RR] This definition as written is seriously dysfunctional on several counts.  It needs attention! Please do NOT use this as a template for MLD association.

 

MTC,

 

RR

 

Regards,

Rojan

 

From: Huang, Po-kai <po-kai.huang@xxxxxxxxx>
Sent: Tuesday, September 1, 2020 2:28 AM
To: STDS-802-11-TGBE@xxxxxxxxxxxxxxxxx
Subject: Re: [STDS-802-11-TGBE] PDT-MAC-MLO: General and Multi-link setup: Procedure

 

Hi Yonggang,

 

              Thanks for the review.

 

              I provide my response in the attachment.

             

Best,

Po-Kai

 

From: Yonggang Fang <yfang@xxxxxxxxx>
Sent: Thursday, August 27, 2020 1:10 PM
To: STDS-802-11-TGBE@xxxxxxxxxxxxxxxxx
Subject: Re: [STDS-802-11-TGBE] PDT-MAC-MLO: General and Multi-link setup: Procedure

 

Hi Po-Kai,

 

Thanks for the preparation.  Attached is my comments and questions.

 

Best Regards

Yonggang Fang

ZTE (TX)

 

Original Mail

Sender: Huang,Po-kai <po-kai.huang@xxxxxxxxx>

Date: 2020/08/26 15:49

Subject: [STDS-802-11-TGBE] PDT-MAC-MLO: General and Multi-link setup: Procedure

Dear all,

 

The proposed spec texts for agreements in MLO-General and MLO-Multi-link setup: Procedure is uploaded.

 

              https://mentor.ieee.org/802.11/dcn/20/11-20-1309-00-00be-proposed-draft-specification-for-ml-general-mld-authentication-mld-association-and-ml-setup.docx

 

              Please take a look and let me know if you have further comments.

 

Best,

Po-Kai


To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1

 


To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1