Hi Dibakar,

Thank you for starting this thread for this CID.

As I also commented, AP should be able to suggest a different TID in the SCS Response if the TID in the SCS Request does not align with the policy on the AP side. And instead of just rejecting  it is better that AP can suggest a TID so that STA can know why the request failed and can take corrective action. I agree with you that this is informational and STA can benefit from knowing why the request was rejected.  

We haven't received any member responses raising concerns on this. I hope members can align on this proposed resolution this time. This was also discussed in the last round as part of my CR doc 23/1540r5.

Others, please share your thoughts on this so we can resolve this.

Thanks,
Binita


On Thu, Apr 11, 2024 at 1:59 PM Das, Dibakar <dibakar.das@xxxxxxxxx> wrote:

Hi all,

 

Thanks for the good discussion on CID 22024 yesterday.

 

22024

35.17

658.48

In the AP suggested QoS Characteristics element in the SCS Response, the UP and TID fields may also be different from the corresponding values in the requested SCS stream, e.g. in the case when the requested UP/TID does not align with the policy on the AP.

Modify text to indicate that UP or TID fields may also differ in the SCS Response.

Revised.

 

Added TID to the list as well. Since UP = TID in the current spec, this also applies to change in UP.

 

TGbe editor: please make changes tagged by CID #22024 in 11-24/0350r0.

 

 

Please let me know your thoughts on how to resolve this.

 

Personally, I think since this is informational, the STA could benefit from knowing why AP rejected its request.

 

Regards,

Dibakar