| Itzik and all,   I have been working on a revision to Table 
275a.  A few observations:   SS/Max_Sleep_Interval/Max. Value seems very 
low.  Shouldn't this be something more like 4,096 frames or 
more?   For SS/Listening_Interval/Min. Value, didn't we 
settle on 4 frames at Session 27?   Thanks all.     
Table 275a—Parameters and 
Constants 
  
  
    | System | Name | Time 
      Reference | Min. 
      Value | Default Value | Max. 
      Value |  
    | SS | Min_Sleep_Interval | Minimum sleeping time allowed to SS | 2 Frames |   |   |  
    | SS | Max_Sleep_Interval | Maximum sleeping time allowed to SS |   |   | 5 Frames |  
    | SS | Listening_Interval | The time duration during which the SS, after waking up and 
      synchronizing with the DL transmissions, can demodulate downlink 
      transmissions and decides whether to stay awake or go back to 
      sleep |   |   |   |  
    | BS | BEA-ADV interval | Nominal time between transmission of BEA-ADV 
      messages |   |   | 30s |  
    | BS | ASC-AGING-TIMER | Nominal time for aging of MSS 
    associations | 100ms |   |   |  
    | BS | Neighbor_Info interval | Nominal time between transmission of Neighbor_Info 
      messages |   |   | 600s |  
    | BS | Neighbor-Aging-Timer | Nominal time for aging of BS neighbor association and removal 
      from the dynamic Neighbor BS table | 3600s |   |   |          Thanks,Phillip 