stds-802-16-mobile: Sleep window parameters in Table 275a



Itzik and all,
 
I have been working on a revision to Table 275a.  A few observations:
 
SS/Max_Sleep_Interval/Max. Value seems very low.  Shouldn't this be something more like 4,096 frames or more?
 
For SS/Listening_Interval/Min. Value, didn't we settle on 4 frames at Session 27?
 
Thanks all.
 
 

Table 275a—Parameters and Constants

System

Name

Time Reference

Min. Value

Default Value

Max. Value

SS

Min_Sleep_Interval

Minimum sleeping time allowed to SS

2 Frames

 

 

SS

Max_Sleep_Interval

Maximum sleeping time allowed to SS

 

 

5 Frames

SS

Listening_Interval

The time duration during which the SS, after waking up and synchronizing with the DL transmissions, can demodulate downlink transmissions and decides whether to stay awake or go back to sleep

 

 

 

BS

BEA-ADV interval

Nominal time between transmission of BEA-ADV messages

 

 

30s

BS

ASC-AGING-TIMER

Nominal time for aging of MSS associations

100ms

 

 

BS

Neighbor_Info interval

Nominal time between transmission of Neighbor_Info messages

 

 

600s

BS

Neighbor-Aging-Timer

Nominal time for aging of BS neighbor association and removal from the dynamic Neighbor BS table

3600s

 

 

 

 

 
 
Thanks,
Phillip Barber