Re: Annex 31B, 31B.2 pause_time





Anand,

Though the pause quantum value is the same as the slot time
for 10/100 ethernet, it is not the same thing. Slot time is
only applicable in half duplex operation while pause quantum
is only applicable in full duplex operation. We changed the
slot time in 1GE without changing the pause quantum. There is
no slot time in 10GE but this does not affect the pause
quantum.

Regards,
Ben

> Anand Dani wrote:
> 
> Hi all,
> 
> In Annex31B, 31B.2 says "The pause_time is measured in units of
> pause_quanta, equal to 512 bit times of the
> particular implementation (See 4.4)." This 512 bit times refers to the
> parameter slotTime for 10 / 100 Mbps defined
> in 4.4.2. For 1 Gbps it is 4096 bit times.
> 
> Since no slotTime is applicable for 10 Gbps what is the value of
> pause_quanta for 10 Gbps ?
> 
> Regards,
> Anand


-- 
-----------------------------------------
Benjamin Brown
AMCC
2 Commerce Park West
Suite 104 
Bedford NH 03110
603-641-9837 - Work
603-491-0296 - Cell
603-626-7455 - Fax
603-798-4115 - Home Office
bbrown@xxxxxxxx
-----------------------------------------