Re: [STDS-802-11-TGBC] Discussion of CIDs 1550, 1264, 1254, and 1247



 

Hi Marc,


Thank you for preparing the resolution for these comment.

I found a few other comments that are essentially asking the same and can be resolved in your document:

 

CID

Commenter

Comment

Proposed Change

1006

Abhishek Patil

Several field names, frame names start with a lower case (e.g., eBCS Info frame, eBCS Request frame etc). Per the IEEE style guide, a (sub)field name or a frame name cannot start with a lower case.

Rename all instances of frame and (sub)field names that start with a lower case. Suggest replacing eBCS xxx with E-BCS xxx or Enhanced Broadcast Service xxx.

1446

Robert Stacey

E-BCS vs eBCS vs EBCS

Choose one an apply consistently. I vote for EBCS (simple acronym that is easy to use throughout).

1142

Hitoshi Morioka

Why use "E-BCS" instead of "eBCS"? Terminology should be consistent.

Replace "E-BCS" with "eBCS".


Regards,

Abhi

 

-----Original Message-----
From: ** STDS-802-11-TGbc -- Enhanced Broadcast Service ** <STDS-802-11-TGBC@xxxxxxxxxxxxxxxxx> On Behalf Of Marc Emmelmann
Sent: Tuesday, January 5, 2021 2:56 AM
To: STDS-802-11-TGBC@xxxxxxxxxxxxxxxxx
Subject: [STDS-802-11-TGBC] Discussion of CIDs 1550, 1264, 1254, and 1247

 

-------------------------------------------------------------------------

CAUTION: This email originated from outside of the organization.

-------------------------------------------------------------------------

 

Please find the following document on mentor:

 

https://mentor.ieee.org/802.11/dcn/21/11-21-0030-00-00bc-discussion-of-cids-1550-1264-1254-and-1247.docx

 

It discusses the CIDs 1550, 1264, 1254, and 1247 to get feedback from the group on how to resolve them.

 

Best,

 

Marc

 